Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Luminescence ; 39(5): e4747, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716575

RESUMO

Atezolizumab (ATZ) is a human monoclonal antibody, which has been granted multiple approvals from the US Food and Drug Administration (FDA) for the immunotherapy of different types of cancer. This study describes the prototype of a time-resolved fluoroimmunoassay (TRFIA) for the quantitation of ATZ in plasma. The assay involved the non-competitive binding of ATZ to its specific antigen [programmed death-ligand 1 (PD-L1) protein]. The immune complex formed on the inner surface of the assay plate wells was quantified by anti-human secondary antibody labeled with a chelate of europium-ethylenediaminetetraacetic acid. The enhanced fluorescence signal was generated by an enhanced fluorescence solution composed of thenoyltrifluoroacetone, trioctylphosphine oxide, and Triton X-100. The conditions of the TRFIA were refined, and its optimum procedures were established. The assay was validated in accordance with the immunoassay validation guidelines, and all the validation parameters were acceptable. The working range of the assay was 20-1000 pg mL-1, and its limit of quantitation was 20 pg mL-1. The assay was applied to the quantitation of ATZ in plasma samples with satisfactory accuracy and precision. The proposed TRFIA has significant benefits over the existing methodologies for the quantitation of ATZ in clinical settings.


Assuntos
Anticorpos Monoclonais Humanizados , Fluorimunoensaio , Fluorimunoensaio/métodos , Humanos , Anticorpos Monoclonais Humanizados/sangue , Anticorpos Monoclonais Humanizados/química , Anticorpos Monoclonais Humanizados/imunologia , Fluorescência , Fatores de Tempo
2.
J AOAC Int ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652601

RESUMO

BACKGROUND: Tulathromycin (TUL) is a triamilide antibacterial drug which has been approved for use in the European Union and the United States for the treatment and prevention of bovine respiratory diseases. The existing methods for determination of TUL in its pharmaceutical bulk form are very limited and suffer from major drawbacks. OBJECTIVES: The aim of this study was the development of two innovative microwell spectrophotometric methods (MW-SPMs) for determination of TUL in its pharmaceutical bulk form. METHODS: The formation of charge transfer complexes (CTCs) of TUL, as an electron donor, was investigated with 2,5-dihydroxy-3,6-dichlorocyclohexa-2,5-diene-1,4-dione (HCD) and 2,3-dichloro-5,6-dicyano-p-benzoquinone (CBQ), as π-electron acceptors. The CTCs were characterized by using UV-visible spectrophotometry and computational calculations. The reactions were employed for the development of two MW-SPMs with a one-step for the quantitative analysis of TUL. RESULTS: The formation of CTCs was confirmed via the formation of characteristic absorption bands with maximum absorption at 520 and 460 nm for CTCs with HCD and CBQ, respectively. The stoichiometry of both CTCs was found to be 1:1, and the values of different spectroscopic and electronic constants confirmed the stability of the CTCs. The mechanisms of the reactions were postulated. The linear range of both MW-SPMs was 10-500 µg/mL. The limits of quantitation were 13.5 and 26.4 µg/mL for methods involving reactions with HCD and CBQ, respectively. Both methods were successfully applied to the quantitation of TUL in pharmaceutical bulk form with acceptable accuracy and precision. The results of eco-friendliness/greenness assessment proved that both MW-SPMs fulfill the requirements of green analytical approaches. In addition, the one-step reactions and simultaneous handling of a large number of samples with micro-volumes in the proposed methods gave them the advantage of high throughput analysis. CONCLUSIONS: This study described two new MW-SPMs as valuable analytical tools for the determination of TUL.

3.
RSC Adv ; 14(12): 8167-8177, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38469186

RESUMO

This study describes, for the first time, the development and validation of a novel ultrasensitive chemiluminescence enzyme immunoassay (CLEIA) for the quantification of atezolizumab (ATZ), a monoclonal antibody approved by the FDA for treatment of different types of cancer. The assay involved the non-competitive binding of ATZ to its specific antigen (PD-L1 protein). The immune complex of PD-L1/ATZ formed on the internal surface of the plate wells was quantified by a novel chemiluminescence (CL)-producing horseradish peroxidase (HRP) reaction. The reaction employed a highly efficient CL enhancer for the HRP-luminol-hydrogen peroxide reaction which was 4-(imidazol-1-yl)phenol. The conditions of the CLEIA and its detection system were refined, and the optimum procedures were established. The CLEIA was validated in accordance with the guidelines of immunoassay validation for bioanalysis, and all the validation criteria were acceptable. The assay's limit of detection and limit of quantitation were 12.5 and 37.5 pg mL-1, respectively, with a working dynamic range of 25-800 pg mL-1. The assay enables the accurate and precise quantitation of ATZ in human plasma samples without any interferences from endogenous substances and/or the plasma matrix. The results of the proposed CLEIA were favourably comparable with those of a pre-validated enzyme-linked immunosorbent assay using a colorimetric detection system. The CLEIA is characterized by simple and high throughput features. The CLEIA is superior to the existing analytical methodologies for ATZ. The proposed CLEIA has a great value in the quantitation of ATZ in clinical settings for assessment of its pharmacokinetics, therapeutic drug monitoring, and refining the safety profile.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...